The symbol on an instrument shows that it can source or measure volts or more, including the combined effect of normal and common mode voltages. The model 2182a6221 combination synchronizes the pulse and measurement. User manual keithley 6221 dc user manual 171 pages. Each new revision includes a revised copy of this print history page. Make all the connections before you turn on the power of your. While viewing the pdf version of this manual, the manual sections can be viewed. Model 2100 6 12digit resolution digital multimeter users manual 210090001 rev. Users manual, quick reference guide, triax cables 2, bnc 10. Instruction manual contains operating and servicing information. Model 2100 6 12digit resolution digital multimeter user.
This users manual supports both the models 2182 and 2182a. The entire pulse, including a complete nanovolt measurement, can be as short as 50s. They provide versions for lv 8 and 2009, and i currently use 2009. Coaxial cables 4 accessories available 2520int1ge integrating sphere 1 inch with germanium detector. Support worldwide technical support and product information ni. Digital io interface a back panel port on every series 2600 instrument provides 14 bits of. Will the 2009compatible drivers be ok with lv 2012. View online or download national instruments ni 6221 user manual. Model 2182a, the model 6221s pulse capability minimizes the amount of power dissipated into a dut. Current source6221 is connected to pc via gpibieee 488 cable.
Do not remove this cap until you are ready to power the system. For the slow setting, the output response of the model 6221 is the same as the out put response of the model 6220. Keithley 6220 ac dc current source 6221 ac and dc current. Users manual for model 2750 multimeterswitch system on. Line synchronization between the model 6221 and model 2182a eliminates power line related noise. We have 1 keithley 6221 manual available for free pdf download. A calibration by customcal is performed by engineers with extensive oem experience. We have decades of expertise in keithley calibration and can possibly repair the keithley 6221 ac and dc current source. The keithley 6221 driver is not a supported national instruments driver, but ill try to help you the best i can. While the 2602a system is easy to install and operate, this manual should be read in full and the information contained herein understood before attempting to place the system in service.
Model 6517a electrometer users manual a greater measure of confidence. Keithley 197a user service manual,circuit diagram, user s manual. Hi im using labview drivers, provided by keithley, to control a keithley 6221 power supply. These allow the user to select waveform parameters, combine multiple waveforms, and select and change any points in a waveform previously created or appended. You will be given prompt assistance and return instructions.
Each h 2s sensor is shipped with a red plastic cap fitted over the sensor head. Ni 6221, ni 6224, ni 6225, and ni 6229 m series devices. How to read data from 2182a nanovoltmeter in basic dc sweep. This will ensure that the easystand 5000 is assembled properly and then used in the most beneficial manner. The cable 8503 has 8 pins connector plugged to the rear panel of 6221 trigger link, and 2. Keithley 660a guarded dc differential voltmeter instruction manual.
The model 62212182a combination synchronizes the pulse and measurementa measurement can begin as soon as 16s after the model 6221 applies the pulse. View online or download keithley 6221 dc user manual. Nanovoltmeter2182a is connected to currentsource via rs232 both side male rs232 and a trigger link. Keithley ultrasensitive current sources series 6200. Select the protection settings menu item and press enter. User manual nord lead a1 nord lead a1r nord keyboards. This manual is an integral part of your standing system and should be read completely and thoroughly by anyone that will be operating the unit. The symbol on an instrument indicates that the user should refer to the operating instructions located in the manual. Users manual for model 2750 multimeterswitch system version 2 created by ankur tomar on jan 19. User manual ni ultiboard user manual may 2008 374488c01.
Commissioning safety systems before power up, verify wiring, terminal connections and stability of mounting for all. Model 6221 ac and dc current source users manual 622x90001 rev. Keithley io layer version c10 windows 10, 8, 7 compatible. Keithley177 microvolt dmm year 1978 service manual,circuit diagram,users manual. Ami recommends that an attendant be present when the easystand 5000 is being used. The cable 8503 has 8 pins connector plugged to the rear panel of 6221 trigger link, and 2 bnc output based on rg58 coaxial cables. Model 2002 multimeter users manual contains operating and servicing information. Fullyguarded fourterminal measurements the 236, 237, and 238 outputs and inputs are fully guarded, and the units are configured to allow fourterminal measurements.
Corporate headquarters 28775 aurora road cleveland, ohio 449 4402480400 fax. C for the model 6220 dc current source and the model 6221 ac and dc current source. I downloaded the keithley driver from keithley s website and was able to access the ke662x vis in labview, but i am unable to locate the ki6220. A g r e a t e r m e a s u r e o f c o n f i d e n c e keithley instruments, inc. Nord lead a1 to an sound system or recording equipment. Model 2001 multimeter operators manual 200190001 rev. Keithley197a user service manual,circuit diagram,users manual. Keithley 177 microvolt dmm year 1978 service manual,circuit diagram, user s manual. Keithley 6517a electrometer users manual wdiskette 90.
Nanovoltmeter2182a is connected to currentsource via rs232. Protection can be turned on or off individually for each channel. Model 2701 instrument networking instruction manual. When protection is on, a user cannot enter a voltage limit larger than the defined maximum.
Please pay close attention to this instruction manual, and read it fully before attempting to operate. The revision level letter increases alphabetically as the manual undergoes subsequent updates. By downloading, you agree to the terms and conditions of the manuals download agreement. When a new revision is created, all addenda associated with the previous revision of the manual are incorporated into the new revision of the manual. Ni 6221 68pin device specifications national instruments. If the product is used in a manner not specified, the protection provided by the product warranty may be impaired. A g r e a t e r m e a s u r e o f c o n f i d e n c e series 2400 sourcemeter users manual 2400s90001 rev. Save the cap and recap the sensor anytime the system power is off for more than one hour. As you have to login to keithley s website to download the drivers, ive attached them.
Current source 6221 is connected to pc via gpibieee 488 cable. H february 2009 model 2001 multimeter operators manual. Users manual for model 2701 ethernetbased dmm data acquisition system on. Users manual for model 2750 multimeterswitch system. Ni vision ni pci1426 user manual base configuration camera link image acquisition device ni pci1426 user manual february 2007 374040c01. Ni pci1426 user manual base configuration camera link image acquisition device ni pci1426 user manual february 2007 374040c01.
Model 6220 dc current source model 6221 ac and dc current source users manual 622x90001 rev. The print history shown below lists the printing dates of all revisions and addenda created for this manual. Pulse delta 6221 and 2182a only provides a pulse output and a 3point or. It is designed to ensure that you maximise your pleasure of. Users manual for model 2701 ethernetbased dmm data acquisition system. As you have to login to keithleys website to download the drivers, ive attached them. The model 6220 dc current source and model 6221 ac and dc current source combine ease of use with exceptionally low current noise. Model 2100 6 12digit resolution digital multimeter users. A manual in pdf format that is stored in the accompanying. I downloaded the keithley driver from keithleys website and was able to access the ke662x vis in labview, but i am unable to locate the ki6220.
Customcal offers these services for the 6221 ac and dc current source at a discount over the oem price. Model 2001 multimeter operators manual mhz electronics. Addenda, which are released between revisions, contain important change information that the user should incorporate immediately into the manual. The reference manual is on the product information cd in pdf format. Page 56 model 62206221 users manual dc current source operation response speed setting 6221 only the filter response speed of the model 6221 can be set for fast or slow. We have 1 keithley 6221 dc manual available for free pdf download. This manual provides instruction for installing and operating the general monitors model 2602a for hydrogen sulfide gas applications. Model name type voltage rating current rating power 2260b3036 360w models 030v 036a 360w 2260b80 360w models 080v 0. Keithley ultrasensitive current sources series 6200 tektronix.
1532 325 44 1111 1586 1052 640 1489 347 1068 1328 1213 601 140 290 611 276 1311 339 1420 213 137 990 892 1408 380 21 519 622 173 636 903 49 347 1453 123 242 679 670 1042 588